Line Filters ensure that the contamination in your system is efficiently reduced. This helps to protect critical processes and equipment. This ensures consistently high quality of air.
Filter Grade GP, HE, AC ,DP | Pipe Size | Flow Rates @ 7 bar g (100 psi g) | |
---|---|---|---|
M3/MIN | cfm | ||
(Grade) 19 | G1/4" | 0.53 | 19 |
(Grade) 40 | G3/8" | 1.12 | 40 |
(Grade) 64 | G 1/2" | 1.80 | 64 |
(Grade) 123 | G3/4" | 3.45 | 123 |
(Grade) 216 | G1 | 6.05 | 216 |
(Grade) 275 | G 5/4" | 7.70 | 275 |
(Grade) 350 | G 3/2" | 9.80 | 350 |
(Grade) 481 | G 3/2" | 13.46 | 481 |
(Grade) 563 | G2 | 15.76 | 563 |
(Grade) 706 | G2 | 19.76 | 706 |
(Grade) 850 | G 5/2" | 23.80 | 850 |
(Grade) 1100 | G3 | 30.80 | 1100 |
(Grade) 1380 | G3 | 38.63 | 1380 |
(Grade) 424 | DN40 | 12.0 | 424 |
(Grade) 669 | DN50 | 19.8 | 669 |
(Grade) 1314 | DN80 | 37.2 | 1314 |
(Grade) 2119 | DN100 | 60.0 | 2119 |
(Grade) 2755 | DN100 | 78.0 | 2755 |
(Grade) 4132 | DN150 | 117 | 4132 |
(Grade) 6886 | DN200 | 195 | 6886 |
(Grade) 11018 | DN250 | 312 | 11018 |
(Grade) 16527 | DN300 | 468 | 16527 |
Grade GP- General Purpose Protection | Grade AC - Activated Carbon Filtration | ||||||||
Particle removal down to 1 micron including coalesced liquid water and oil,providing a maximum remaining oil aerosol content of 0.5 mg/m3 @21°C | Oil vapour and hydrocarbon odour removal, giving a maximum remaining oil content of<0.003 mg/m3 (<0.003 ppm) (excluding methane) @21°C. (Precede Grade AC with Grade HE filter). | ||||||||
Grade HE- High Efficiency Oil Removal Filtration | Grade DP - General Purpose Dust Filtration | ||||||||
Particle removal down to 0.01 micron including water and oil aerosols, providing a maximum remaining oil aerosol of 0.01 mg/m3 @ 21°C (Precede with Grade GP filter). | Dust particle removal down to 1 micron |
Operating Limitations | |||||||||
Maximum operating pressure | 16 bar g | (232 psi g) | Maximum recommended operating temperature (Grade AC) | 30°C | (86°F) |